++

MwPharm++ Release 1.1.8 - Description
contact us

Contact us

Address

MEDIWARE a.s.
Na Viničních horách 1834/24
160 00 Praha 6

Technical support:

Tel: +420 773 760 568

Email: support@mediware.cz


Jiří Douša

Tel: +420 774 435 341

Email: george.dousa@mediware.cz

MwPharm++ Release 1.1.8 - Description

MwPharm++/Edsim++ Release 1.1.8 - Description

 

PR-205 Cannot load curves when system decimal point is not dot (".").
PR-206 Incorrect window size when running under windows 8.1 and IDE  (side effect of CR-182)
PR-207 Fixed issue in the plugin framework when clicking list boxes under windows 8.1 (prevents low level crash)
PR-208 Parameter scaling exponent forced to 1.0 for unit formats 0 and 1 (no allometric scaling)
PR-209 TCoElimination must inherit Target attribute from TElimination (was set to null) in order to connect to TMetabolism
PR-210 TCovariate base class must limit source (Source attribute) to BPatient derived objects
PR-211 Creatinine PreFit function in TPatient(Ex) broken ("calculate exact").
PR-212 Internal synthetic observations exposed in TPatientEx
PR-213 Interactant compartment baseline incorrectly calculated if connected to a TCompetition interaction object
PR-214 Crash when specifying an invalid external in the Ext sheet followed by switching to the Opt sheet
PR-215 TLevelA object broken (because of symbol array support)
PR-216 Sim, Fit and App settings not read when no object has been selected
PR-217 Fixed a problem when compiling and running macro models (due to incorrect initialization, fixed using Rebuild)
CR-182 Updated internal components (syntax editor, flow chart and spreadsheet)
CR-183 Objects derived from TInputEV (e.g. TAbsorption) and TInputDist (e.g. TGamma) can now target TInputEV derived objects
CR-184 Like CR-172 but keep "Variable" as axis title in case of multiple series
CR-185 Variables of type TIntVariable are not required anymore to reset their ObservationIndex property in the Final event
CR-186 Do not show observations in chart in case the X-axis does not represent the simulation time
CR-187 Patient objects are now automatically linked as source objects (no link required anymore, usefull in complex models)
CR-189 PKPD Object library is now using the molecular weight ratio when transfering material between objects
CR-190 Locked fixed variable units in user interface
CR-191 Improved TObject reflection handling
CR-192 Added Connect TObject event for handling dynamic unit and subtsance changes (as an alternative for Final event)
CR-193 Added "bool pre" parameter to TObject Event procedure. Is called before event (pre = false) and aftere event (pre = true)
CR-194 Completely redesigned the baseline calculation procedure in TCompartment (C# dynamic not required anymore).
Hospital

Hospital

MwPharm++ is an efficient TDM software primarily to establish proper dosing regimen based on population PK.

read more
Hospital

Doctor

MwPharm Online Calculator is ideal tool for initial dose adjustment based on patient physiology and approate package size selection.

read more
Hospital

Health insurance

MwPharm Revision System enables better control, more effective treatment and cost savings.

read more
Hospital

Research & university

Research or teaching on PKPD? Edsim++ is ideal tool for you.

read more
mediware mediware mediware mediware mediware
Try it MWPharm Online